Metal tube float (rotor) flowmeter-SN60A
Home / Products / Serie de Flujo / Medidor de Flujo / Metal tube float (rotor) flowmeter-SN60A

If you have any further questions, please call +86-021-37566990 or fill out the inquiry form.

Product 3D Image
Get coupons

Metal tube float (rotor) flowmeter-SN60A

Product introduction

Metal tube float flowmeter (metal tube rotor flowmeter) is a commonly used in industrial automation process control of a variable area flow measurement instrument. It has a small size, large detection range, easy to use and so on, it can be used to measure the flow of liquids, gases and steam, especially suitable for low-flow rate and small flow measurement. Over the years, the metal tube float flowmeter with its excellent performance and reliability, as well as a better performance-price ratio, in the petrochemical, iron and steel, electric power, metallurgy, light industry, food, pharmaceutical, water treatment and other industries have been widely used. This manual is aimed at professional and technical personnel, applicable to the design and selection of metal tube float flowmeter, but also can be used for end-users in the use of reference. The manual introduces the working principle, functional characteristics, technical parameters, instrument type and shape, flow calculation, wiring and installation, maintenance, etc. of metal tube float flowmeter. This manual is only for the design selection and use of metal tube float flowmeter, while the manufacturer reserves the right to improve some technical parameters without prior notice. Reliable and maintenance-free

Functional Features Measuring Principle Measurement Schematic Technical Parameters Dimension Drawing Wiring Diagram Installation Selection Table

Suitable for small diameter and low flow rate media flow measurement
- Reliable, low maintenance and long life
-Low requirements for straight pipe sections
- Wide range ratio 10:1
-Dual line LCD with instantaneous/accumulative flow display
- Keypad on the indicator, easy to operate and set up
- All-metal construction, suitable for high temperature, high pressure and strong corrosive media.
Non-contact magnetic coupling drive
-Can be used in flammable, explosive hazardous occasions
- DC power supply or battery power supply available
With data recovery, data backup and power-down protection function.
-Multi-parameter calibration function

Metal tube float flowmeter mainly consists of two main components: sensor and indicator. The sensor consists of a connecting flange, a measuring cone, a float and an upper and lower guide; the indicator consists of a shell, a magnetic drive system, a dial and an electrical telemetry system. Inside the vertical conical measuring tube, there is an upward and downward movable measuring part, the float (Figure 1). When the fluid passes through the conical tube from bottom to top, the float is forced by the fluid and moves upward along the conical tube. As the fluid flow increases, the displacement of the float increases; conversely, as the fluid flow decreases, the displacement of the float decreases. In other words, the flow rate of the fluid determines the position of the float in the measuring tube and thus the size of the annular area between the float and the conical tube. When the fluid flow is maintained at a constant flow rate Q, the float is in dynamic equilibrium at position h in the conical tube, where the annular area between the float and the conical tube remains constant. The float is subjected to three forces: the gravitational force of the float G, the buoyant force of the float F, and the force of the fluid on the float P. These three forces are in equilibrium. According to the fluid dynamics of the Park's endeavour equation, the principle of force equilibrium and the law of fluid continuity, it can be calculated at this time through the annular area of the instantaneous fluid flow, so the metal tube float flowmeter is the principle of variable area measurement of flow. Figure 1 Inside the float, embedded in a high-performance permanent magnet, when the float is in the equilibrium position, the float around the formation of a uniform and stable magnetic field. On the outside of the conical tube, a magnetic sensor is installed, so that the linear displacement of the float in the measuring tube can be transmitted to the indicator through non-contact form, and after detection and processing, it is finally displayed on the indicator dial or output the corresponding standard 4-20mA current signal.

Meter aperture  DN15, DN25, DN50, DN80, DN100, DN150
 (for other calibres please consult the manufacturer)
Flow range  Liquid: 1.0~150,000l/h Gas: 0.05~3000m3/h
(See page 11 for flow rate range.)
Range ratio  10 :1 , 20 :1 (special) 
Accuracy  Level 1.5 , Level 1.0 (special)
Pressure rating  DN15, DN25, DN50: 4.0MPa (max. 20MPa)
 DN80, DN100, DN150: 1.6MPa (max.: DN80: 10MPa;
 DN100: 6.4MPa; DN150: 4.0MPa)
Medium temperature  Standard: -30℃ ~ +120℃ , High temperature: 120℃ ~ 350℃ 
Power supply  24VDC (12 ~ 36VDC), 220VAC 
Output signal  4 ~ 20mADC (2-wire), can be attached to the HART protocol 
Output load  500Ω (24V power supply) 
Ambient temperature  Local type: -40℃ ~ 120℃ Remote type: -30℃ ~ 60℃ 
Storage conditions  Temperature: -40℃ ~ 85℃ Humidity: ≤ 85
Connection method  Flange connection, flange standard: GB/T9119-2000, users can specify
 (other connections can be negotiated with the manufacturer)
Cable connection  M20 × 1.5, 1/2 NPT 
Shell protection  IP65 
Explosion-proof symbol  Intrinsically safe: Ex ia IICT6, Explosion-proof: Ex d IICT6
Viscosity of the medium  DN15:  η < 5mPa.s       DN25:  η  < 250mPa.s
    DN50~ DN150:  η < 300mPa.s
Material of the connection R1: 304 , 06Cr19Ni10 R0: 316 , 06Cr17Ni12Mo2
RL: 316L , 022Cr17Ni12Mo2 Ti: Titanium alloy
RP: PTFE lining

SN60A- A B C D E F G H elaborate on
SN60A-                 SN60A Series Metal Tube Float Flowmeter 
Measuring tube structure               Bottom Input and Output
              Top Input and Output
              Bottom Input and Output
              Bottom Transverse Input and Output
              Right Input and Output
              Left Input and Output
Catch material R0             Stainless Steel 316
R1             Stainless Steel 304
RP             PTFE (PTFE)
Ti             Titanium Alloy
RL             Stainless Steel 316L
HC             Hastelloy C 
Pipe calibre DN …           Calibre Selection: DN15, DN 25, DN 50,
DN 80, DN 100, DN 125, DN 150, DN 200
K…           Hygiene K15, K20, K25, K32, K38, K51, K63, K76, K101
add-on structure T         Jacketed
Z         Damped
G         High-temperature
Y         High-pressure
Indicator form code combinations M0       In-situ indicator, mechanical pointer to indicate instantaneous flow
M1       Square housing, mechanical pointer for instantaneous flow, LCD for instantaneous/cumulative flow
M2       Round housing (white), mechanical pointer for instantaneous flow,
also available with LCD for instantaneous/cumulative 
M3       Buccaneer housing (square), mechanical pointer for instantaneous flow,
also available with LCD for instantaneous/cumulative 
M4       Round housing (M40), mechanical pointer for instantaneous flow,
also available with LCD for instantaneous/cumulative flow
M5       Mechanical pointer for instantaneous flow,
also with LCD for instantaneous/accumulative flow 
M6       Small round stainless steel housing, mechanical pointer for instantaneous flow,
also with LCD for instantaneous/accumulative flow 
M7       Small stamped stainless steel housing, mechanical pointer for instantaneous flow
M8       Stamped large stainless steel housing, mechanical pointer to indicate instantaneous flow,
also available with instantaneous/accumulative flow display
M9       Round housing (blue), mechanical pointer for instantaneous flow, also available with instantaneous/cumulative flow on LCD flow rate,
instantaneous/cumulative flow rate can also be displayed on the LCD
M10       Stamped Stainless steel housing (diameter 146 mm), mechanical pointer for instantaneous flow
M11       Round housing (M30), mechanical pointer for instantaneous flow
Instantaneous/cumulative flow also available on LCD
M12       Round housing (double wiring holes), mechanical pointer for instantaneous flow
Instantaneous/cumulative flow also available on LCD
Power supply method     Battery operated, not available
A     224VDC 2-wire power supply, 4-20mA signal output, without backlight
B     24VDC 3-wire and 4-wire power supply
C     24VDC 2-wire power supply, 4-20mA signal output, with backlight available
D     24VDC 3-wire and 4-wire power supply, 4-20mA signal output, with backlight
Explosion-proof symbol M   General non-explosion-proof
i   Intrinsically safe Ex ia Ⅱ CT6
d   Explosion-proof Ex d Ⅱ CT6
Alarm or pulse output KO No alarm or pulse output
K1 Lower-limit alarm or one pulse output
K2 Upper-limit and lower-limit alarms or double pulses
K3 Upper-limit and lower-limit alarms or double pulse outputs
* The selection table is for parameter selection only and is shipped with the corresponding code for the parameter.
Shanghai Kayuan Electronic
Technology Co., Ltd.

Shanghai Kayuan Electronic Technology Co., Ltd. es una empresa especializada en la producción e investigación y desarrollo (I+D) de sensores y controladores de fluidos industriales. Nuestros productos principales incluyen interruptores y sensores para medición de flujo, presión, temperatura y nivel de líquidos.

En el año 2008, establecimos nuestra planta de ensamblaje en Shanghái, China, para fabricar la serie de productos de PAKU. Adoptamos tecnología avanzada y procesos de fabricación modernos en todas nuestras operaciones. Gracias a nuestra tecnología de diseño y producción profesional, completa gama de productos, excelente calidad y red de servicios de ventas, podemos ofrecer a los usuarios no solo soporte técnico profesional y oportuno, sino también servicios integrales de alta calidad.

La empresa ha establecido diversos departamentos, como compras, I+D, gestión de calidad, finanzas, ventas, servicio postventa, oficina general, laboratorio, sala de archivo, taller de calibración, taller de producción, área de inspección, zona de almacenamiento, área de envío y una sala de descanso para tomar té, con el objetivo de proporcionar productos de excelente calidad y servicios sinceros.

Adherimos al concepto centrado en el cliente de crear valor para los mismos. De acuerdo con las necesidades del sector industrial de nuestros clientes, actualizamos continuamente nuestra tecnología y optimizamos nuestros servicios, con la visión de convertirnos en líderes en el campo de la automatización de procesos.

Los productos de PAKU se utilizan ampliamente en diversas industrias, incluyendo equipos completos de automatización, equipos petroleros, equipos químicos, equipos eléctricos, equipos de soldadura, equipos siderúrgicos, equipos metalúrgicos, industria automotriz y tratamiento de aguas. Hemos servido a numerosos clientes tanto nacionales como internacionales, y nuestros productos se exportan a países como Canadá, Estados Unidos, Brasil, Indonesia, Vietnam, Tailandia y Rusia.

En el cada vez más competitivo mercado global del futuro, PAKU continuará sirviendo, como siempre lo ha hecho, a una amplia gama de clientes nacionales e internacionales con calidad excepcional, precios razonables y competitivos, entregas puntuales y un servicio postventa perfecto. Damos la bienvenida a una amplia cooperación con clientes OEM (fabricantes de equipos originales) y ODM (fabricantes de diseño original).

Puntos clave para la instalación de medidores de flujo electromagnético.

Seleccionar la ubicación de instalación: Para hacer que el medidor de flujo electromagnético funcion...

Cableado del medidor de flujo electromagnético.

1. Cuanto más corto sea el cable de señal, mejor. 2. El cable de señal debe estar estrictamente sepa...

Selección de la posición de recepción del medidor de flujo electromagnético.

La señal generada por el transmisor electromagnético es débil, por lo que es un factor importante ha...

Colocación de cables en el sitio para medidores de flujo electromagnéticos.

Actualmente, la colocación de cables se divide en dos tipos: colocación abierta y colocación oculta....